Cover of: Intramedullary Rods | J. Paul Harvey Read Online
Share

Intramedullary Rods Clinical Performance and Related Laboratory Testing (Astm Special Technical Publication// Stp) by J. Paul Harvey

  • 817 Want to read
  • ·
  • 84 Currently reading

Published by Astm Intl .
Written in English

Subjects:

  • Orthopedics,
  • Science/Mathematics,
  • Medical Engineering

Book details:

The Physical Object
FormatPaperback
Number of Pages196
ID Numbers
Open LibraryOL7904609M
ISBN 100803111819
ISBN 109780803111813

Download Intramedullary Rods

PDF EPUB FB2 MOBI RTF

Intramedullary Rods: Clinical Performance and Related Laboratory Testing (Astm Special Technical Publication) [Harvey, J. Paul] on *FREE* shipping on qualifying offers. Intramedullary Rods: Clinical Performance and Related Laboratory Testing (Astm Special Technical Publication)Cited by: 3. ISBN: OCLC Number: Notes: "ASTM publication code number " Papers presented at the ASTM Symposium on Femoral Intramedullary Rods: Clinical Performance and Related Laboratory Testing, held May, in Cincinnati, Ohio and sponsored by the ASTM Committee F-4 on Medical and Surgical Materials and . intramedullary nailing through an antegrade or retrograde insertion site • Proximal or distal 1/3 fractures MAY be managed best with a plate or an intramedullary nail depending on the location and morphology of the fracture. ISBN: OCLC Number: Notes: "ASTM publication code number " Papers presented at the ASTM Symposium on Femoral Intramedullary Rods: Clinical Performance and Related Laboratory Testing, held May, in Cincinnati, Ohio and sponsored by the ASTM Committee F-4 .

S aureus also causes invasive infections with bacteremia associated with foreign bodies, including intravascular catheters or grafts, peritoneal catheters, cerebrospinal fluid shunts, spinal instrumentation or intramedullary rods, pressure equalization tubes, pacemakers and other intracardiac devices, and prosthetic joints. Intramedullary rodding can be performed once there are symptomatic fractures. The entry portal of the femur is situated at the tip of the greater trochanter. For the tibia, the entry portal is.   I would suggest using CPT Per the CPT book (pg ), "Open treatment is used when the fractured bone is either: 1) surgically opened (exposed to the external environment) and the fracture (bone ends) visualized and internal fixation may be used; or 2) the fractured bone is opened remote from the fracture site in order to insert an intramedullary nail . Intramedullary is a medical term meaning the inside of a bone. Examples include intramedullary rods used to treat bone fractures in orthopedic surgery and intramedullary tumors occurring in some forms of cancer or benign tumors such as an enchondroma. ReferencesFMA:

Orthopedic Hardware Atlas. Basic Orthopedic Hardware. Internal Fixation Hardware. Screws; Plates; Pins and Wires. CONTAINED IN VOL Outlines a way for static bend and torsion testing of intramedullary rods for the evaluation of bending strength, bending, and torsional rigidity. General Product Information - (Show below) - (Hide below). Intramedullary nails, also called intramedullary rods, are used in the medullary cavity of bone. Intramedullary nails are used to treat fractures of long bones in the body. These nails are traditionally triangular or V-shaped, with a cross-section. In book: Intramedullary Limb Lengthening (pp) nails that utilize telescopic rods with internal ratchet mechanisms that elongate the bone. system is comparable to that of other.